Paper Plastic Composite Film Oxygen Transmission Rate Test System

Model NO.: OX2/231
Power Source: AC220V
Certifications: ISO Ce
Warranty: 12 Months
After-Service: Online, in Field
Trademark: Labthink
Transport Package: Veneer Case
Origin: Shandong
Model NO.: OX2/231
Power Source: AC220V
Certifications: ISO Ce
Warranty: 12 Months
After-Service: Online, in Field
Trademark: Labthink
Transport Package: Veneer Case
Origin: Shandong
Paper Plastic Composite Film Oxygen Transmission Rate Test System

OX2/231 is based on the equal pressure method, and is professional applicable to the determination of oxygen transmission rate of film and package products, including plastic films, composite films, sheeting, plastic bottles, plastic bags and other packages.

Paper Plastic Composite Film Oxygen Transmission Rate Test System





Features
  • Tests 3 equivalent specimens at one operation and exports test results in average value
  • 2 test modes for both films and packages, and accessories for package test are available for customization
  • Equipped with constant temperature and humidity control devices (optional parts) to meet different test requirements
  • Reference film for fast calibration to ensure accurate and universal test data
  • The instrument is controlled by micro-computer with LCD, menu interface and PVC operating panel, which could conveniently export test data, test results and test curves
Applications
 
  • Films
    Including plastic films, plastic composite films, paper-plastic composite films, coextruded films, aluminized films, aluminum foils, aluminum foil composite films and many others
  • Sheeting
    Including various sorts of engineering plastics, rubber and building materials, e.g. PP, PVC and PVDC
  • Packages
    Including plastic, rubber, paper, paper-plastic composite, glass and metal packages, e.g. Coke bottles, peanut oil packages, Tetra Pak materials, vacuum bags, metal three-piece cans, plastic packages for cosmetic, soft tubes for toothpaste, jelly and yogurt cups

Specifications
 
Specifications Film Test
Package Test
(customization available)
Test Range 0.01 ~ 1000 cm3/m2·d (standard)
0.1 ~ 10,000 cm3/m2·d (optional)
0.0001 ~ 10 cm3/pkg·d (standard)
Number of Specimens 1 ~ 3
Resolution 0.01 cm3/m2·d 0.0001 cm3/pkg·d
Temperature Range 15°C ~ 55°C (optional) /
Temperature Accuracy ±0.1°C /
Humidity Range 0%RH, 15%RH ~ 90%RH, 100%RH 
(optional)
Humidity Accuracy ±1%RH
Test Gas O2 and air (outside of supply scope)
Test Area 50 cm2 /
Thickness ≤3 mm (customization is available for other thickness) /
Specimen Size 108 mm x 108 mm Test in 100% O2: Specimen should be smaller than Ф120 mm and lower than 360 mm
Test in the Air: No size limitation
Bottles: the inner diameter should be bigger than Ф8 mm, outer diameter should be smaller than Ф42 mm (Standard)
Bags or Boxes: Supported by accessories
Carrier Gas High purity nitrogen with more than 99.999% concentration
(outside of supply scope)

Standards

ISO 15105-2, GB/T 19789, ASTM D3985, ASTM F2622, ASTM F1307, ASTM F1927, JIS K7126-2, YBB00082003

Paper Plastic Composite Film Oxygen Transmission Rate Test System

OX2/231 is based on the equal pressure method, and is professional applicable to the determination of oxygen transmission rate of film and package products, including plastic films, composite films, sheeting, plastic bottles, plastic bags and other packages.

Paper Plastic Composite Film Oxygen Transmission Rate Test System





Features
  • Tests 3 equivalent specimens at one operation and exports test results in average value
  • 2 test modes for both films and packages, and accessories for package test are available for customization
  • Equipped with constant temperature and humidity control devices (optional parts) to meet different test requirements
  • Reference film for fast calibration to ensure accurate and universal test data
  • The instrument is controlled by micro-computer with LCD, menu interface and PVC operating panel, which could conveniently export test data, test results and test curves
Applications
 
  • Films
    Including plastic films, plastic composite films, paper-plastic composite films, coextruded films, aluminized films, aluminum foils, aluminum foil composite films and many others
  • Sheeting
    Including various sorts of engineering plastics, rubber and building materials, e.g. PP, PVC and PVDC
  • Packages
    Including plastic, rubber, paper, paper-plastic composite, glass and metal packages, e.g. Coke bottles, peanut oil packages, Tetra Pak materials, vacuum bags, metal three-piece cans, plastic packages for cosmetic, soft tubes for toothpaste, jelly and yogurt cups

Specifications
 
Specifications Film Test
Package Test
(customization available)
Test Range 0.01 ~ 1000 cm3/m2·d (standard)
0.1 ~ 10,000 cm3/m2·d (optional)
0.0001 ~ 10 cm3/pkg·d (standard)
Number of Specimens 1 ~ 3
Resolution 0.01 cm3/m2·d 0.0001 cm3/pkg·d
Temperature Range 15°C ~ 55°C (optional) /
Temperature Accuracy ±0.1°C /
Humidity Range 0%RH, 15%RH ~ 90%RH, 100%RH 
(optional)
Humidity Accuracy ±1%RH
Test Gas O2 and air (outside of supply scope)
Test Area 50 cm2 /
Thickness ≤3 mm (customization is available for other thickness) /
Specimen Size 108 mm x 108 mm Test in 100% O2: Specimen should be smaller than Ф120 mm and lower than 360 mm
Test in the Air: No size limitation
Bottles: the inner diameter should be bigger than Ф8 mm, outer diameter should be smaller than Ф42 mm (Standard)
Bags or Boxes: Supported by accessories
Carrier Gas High purity nitrogen with more than 99.999% concentration
(outside of supply scope)

Standards

ISO 15105-2, GB/T 19789, ASTM D3985, ASTM F2622, ASTM F1307, ASTM F1927, JIS K7126-2, YBB00082003

Shell And Tube Heat Exchanger

A shell and tube heat exchanger is a type of heat exchanger that is commonly used for heating, cooling and condensing applications. lt consists of a shell with an internal bundle of tubes,which allows the hot and cold fluids to pass through the walls of the exchanger and exchange their energy. Shell and tube exchangers are classified in several ways, including design, operational construct, and construction materials. Mainly Fixed Tube Heat Exchanger, Floating Head Heat Exchanger, U-tube Heat Exchanger, and double tube heat exchanger.



The working principle of a shell and tube heat exchanger is relatively simple. The system is designed with two separate flows on either side of the heat exchanger. The primary flow of the hot fluid passes through the tubes, while the secondary flow of the cold fluid passes through the spaces between the tubes. Heat is then transferred from the hot side to the cold side via conduction, leading to an exchange of temperatures.



Shell and tube heat exchangers are normally used in process plants and used in a wide range of applications. A case in point is the cooling of condensates in refineries and nuclear power plants. In this application, condensate is heated using an external source and passed through the tube section of the heat exchanger. This condensate is then cooled and condensed as it passes through the shell side, where the heat is transferred to a cooling medium such as water, steam or oil.

Shell And Tube Heat Exchanger,Fixed Tube Sheet,Shell Tube Heat Exchanger,Split Ring Floating Head Heat Exchanger

Guangdong Jiema Energy Saving Technology Co.,Ltd , https://www.jmheatexchanger.com